1500 kva Pad Mounted Transformer widely used in power distribution systems, solar energy systems and Crypto Mining
ANSI, DOE, IEEE, CSA and IEC standards and UL
Inquiry Now
Conection group | Dyn1/Ynyn0 |
Type | Loop Feed or Radial Feed |
Capacity | 1500kva |
Primary Voltage | 7.2 kV/13.8 kV/34.5kV Delta/Wye |
Winding Material | Cooper or Aluminium |
Core Legs | 3 or 5 |
Vector Group | DYN1 or YNYN0 |
Cooling Method | ONAN or KNAN |
Warranty | 24 Months |
1500 kva Pad Mounted Transformer can be designed to UL listed standards and feature fully enclosed tamper-resistant terminal compartments, available in pre-dead or pre-live configurations, for loop or radial feed applications, using mineral oil, or environmentally friendly Envirotemp™ FR3™.
Jiangsu Daelim has a team of more than 10 engineers with more than 20 years of experience in transformer design and the latest production equipment, so it has the ability to design and quickly deliver to meet any customer's custom transformer needs. Daelim’s 1500 kva pad mounted transformers can not only meet ANSI, IEEE, CSA IEC standards, but also meet DOE efficiency values.
Daelim has.installation and after-sales teams.in North America and South America, such as the United States, Canada, Chile, Ecuador and other countries, so you don't have to worry about installation and after-sales problems. Three Phase Pad Mounted Transformerl are made with the highest quality materials and are widely used in residential complexes, commercial centers, airports, stations, schools, solar boost, manufacturing facilities, industrial applications and crypto mining/bit coin mining.
Daelim has provided effective power solutions for many crypto mining customers in the United States, Canada, and Venezuela, saving customers a lot of time and cost.If you also have pad mounted transformer needs, please contact us, we can provide you with an effective solution.
1500 kva pad mounted transformer is oil filled transformer. Daelim can produce two types of this Pad Mounted Transformer. Loop feed (hav 6 HV bushings) and Radial feed (have 3HV bushings). ELSP fuse, Bay-O-Net Fuse, LB switch, breaker are all available based on your needs.
The following table is the standard pad mount transformer parameters provided by our factory. Daelim can design and manufacture three phase transformers that meet CSA, ANSIIEEE and US DOE efficiency values. Generally, a 1500KVA transformer weight about 4 tons If you have special needs, you can contact us, and our professional engineers can give you design plans and outline drawings.If you need padmounted transformer catalogs, quality documents, services document, etc., you can download.
Rating | No Load Loss | On load Loss | W(mm) | D(mm) | H(mm) | Oil Weight(kg) | Tatal Weight(kg) |
75kVA | 180 | 1250 | 1390 | 910 | 1430 | 120 | 645 |
150kVA | 280 | 2200 | 1510 | 980 | 1530 | 201 | 989 |
225kVA | 400 | 3050 | 1600 | 1000 | 1660 | 230 | 1195 |
300kVA | 480 | 3650 | 1660 | 1080 | 1680 | 260 | 1415 |
500kVA | 680 | 5100 | 1810 | 1160 | 1790 | 325 | 1905 |
750kVA | 980 | 7500 | 2030 | 1300 | 2030 | 535 | 2755 |
1000kVA | 1150 | 10300 | 1651 | 1549 | 1854 | 650 | 3235 |
1250kVA | 1360 | 12000 | 2100 | 1500 | 2050 | 680 | 4050 |
1500kVA | 1640 | 14500 | 2210 | 1470 | 2150 | 748 | 4200 |
2000kVA | 1940 | 18300 | 2380 | 1600 | 2220 | 850 | 4600 |
2500kVA | 2500 | 25500 | 1730 | 2100 | 2300 | 1450 | 4900 |
2750kVA | 2600 | 23600 | 1880 | 2300 | 2360 | 1800 | 6300 |
3000kVA | 2730 | 27000 | 2400 | 2600 | 2400 | 2400 | 7000 |
3750kVA | 3500 | 38000 | 2500 | 2700 | 2600 | 2800 | 7200 |
In order to reduce turbine loss and hysteresis loss, Daelim use 0.27-0.35MM thick cold-rolled silicon steel sheet (grade 70, 80, 90) with lower unit loss as the iron core of the three phase pad mount transformer. And it adopts 45-degree multi-level full oblique stacking, which can not only reduce the no-load loss of the transformer for you, but also reduce the noise and improve the performance of the transformer.
The winding is the circuit part of the three phase pad mount transformer, which is generally made of copper or aluminum wire wrapped with insulating paper and then wound. Based on the customer's requirements for the technical parameters of the three phase pad mounted transformer, Daelim use the copper wire or aluminum wire with the most suitable cross-sectional area to help you reduce costs while reducing the load loss of the transformer,Transformer Standard.
The information on the transformer nameplate includes:
Transformer capacity;
HV, LV, Bay-onet-fuse model;
Transformer oil weight;
Total transformer weight;
Transformer efficiency value;
Current limting fuse model;
Tap change voltage regulation range table;
Electrical connection diagram; Transformer Conection group chart.
1.Compact structure, small size, convenient installation, flexible maintenance and maintenance
2.Fully insulated, fully sealed structure, safe and reliable, and reliable protection of personal safety;
3.The high-voltage side is protected by double fuses, among which the fuse of the plug-in fuse is a double sensitive fuse (temperature, current), and the backup fuse is a current-limiting fuse, which reduces the operating cost;.
4.The high-voltage incoming line adopts the cable connector structure, which is fully insulated, safe and reliable, and easy to operate;
5.It can be used for both ring network and terminal, the conversion is very convenient, and the reliability of power supply is improved
6.The transformer is a three-phase three-column or three-phase five-column structure, and the iron core adopts a stepped seam process or a wound iron core process, which has low noise, low loss, and strong resistance to short circuit and overload.
7.Special process of vacuum drying and vacuum oil injection
8.The cabinet can adopt anti-corrosion design and special paint treatment according to the requirements of the operating environment, and has the functions of "three defenses", that is, anti-condensation, anti-salt spray, and anti-mold functions, and can meet the anti-corrosion requirements in high temperature and high humidity environments.
DAELIM’S Three Phade Pad Mounted Transformer has strict experimental test before shipment to ensure the quality of the transformer.Transformer routine experimental projects are of the following types:
1.Measurement of voltage ratio. .
2. Measurement of winding resistance.(Routine)
3. No-load loss and no-load current test.
4. Load loss and Short circuit test.
5. Applied voltage test.
6. Induced Over Voltage Withstand Test
7. Insulation Resistance test
8. Other Information.
9. Leakage test(Routine)
10. Outer inspection
If you has other transformer experimental project requirements, we can also provide.
Beijing Dalin has ISO9001 quality management system certification, ISO14001 environmental management system certification, ISO45001 occupational health and safety management system certification, product certificates and experimental reports, including CSA, SGS, UL, etc., to ensure the quality of transformers from all aspects, To meet the needs of customers in the international market.
General 1500 kva pad mounted transformer accessories include: HV Bbushing; Bay-O-Net Fuse; Tap Changer; Load Break Switch; Parking Stand; Drain Valve; Oil Level Indicator; Pressure Relief valve; Pressure Indicator;.ELSP Fuse; Thermometer. Daelim can provide three phase pad mounted transformer accessories of international famous brands, such as qualitrol, ABB, etc. Daelim's three phase pad mounted ransformer accessories can meet CSA/ANSI/IEEE and other standards.
Jiangsu Daelim generally use wooden boxes with wooden pallets, and the solid wood used is fumigated to prevent corrosion and insects.Or more customer requirements for packaging and transportation. With nearly 20 years of transformer export experience, Daelim can help you deliver three phase pad mounted transformers to your project quickly and safely.
Jiangsu Daelim have more than 100 workers and advanced production equipment, with monthly production capacity of more than 300 sets three phase pad mounted transformers.Fast delivery capability, generally 8-10 weeks.
In the past two years, Delim has exported more than 1,000 sets pad mounted.transformers to the North American market, mainly in the United States and Canada. Many padmoutned transformers purchased by Daelim’s customers are used in Crypto Minings, and the number is relatively large.
Jiangsu Daelim also provides single phase pad mounted transformer, and exported hundreds of units to North America, so if you have any single phase padmounted transformer needs, please send them to us.
If you need the technical parameters, outline drawing and price list of the transformer, please leave a message